Troubleshooting Instructions (internal) - only for out of warranty cases
  1. Help Center
  2. Troubleshooting
  3. Troubleshooting Instructions (internal) - only for out of warranty cases

Time-based-triggering test

To check if the camera mount (seagull cable) is damaged, the customer can test the triggering of images without flying.

Only use this instructions if really required. We want to prevent providing the WingtraMode password to customers as much as possible!

 

If you get the chance to test, here are brief instructions:

- Go to WingtraMode from General Settings (pw: wingtra.1)

- Unlock parameters by setting: PARAM_UNLOCK = 20170109

- Save params on reboot by setting: SYS_STABLE_PARAM = "Keep current params on reboots"

- Set TRIG_MODE = "Time based, always triggering"

- Repower the plane, after the camera connected it should start taking images by itself. If it does that, then the test has succeeded.

- Unlock parameters by setting: PARAM_UNLOCK = 20170109

- Save params on reboot by setting: SYS_STABLE_PARAM = "Reset params to default on reboot"

- Repower plane and confirm that it is not triggering anymore and the tabs on the left are NOT red.

- Go back to Basic Mode from General settings